- Implications of Human Behaviour
- Types of Safety Equipment
- Safety Measures During Preventive Maintenance
- Crane Handling Safety
- Generator Handling Safety
- Motor Handling Safety
- Transformer Safety
- Bonding
- Safety Measures During Handling Lighting Protection Equipment
- Precautions Against Highly Flammable Contents
- Secondary Ex-Protection
- Primary Ex-protection
- Duties and Obligations
- Maintenance of Unprotected Equipment
- Procedure to Mark Unprotected Equipment
- Test Certifications
- Safe Electrical Equipment Design Characteristics
- Protection Against Weather Complexities
- Classification of Temperature
- Safety Measures Related to Gas/Ducts/Fibre material
- Classification of Hazard-Prone Areas
- Cables
- Types of the Supply System
- Earthing
- Earth Fault Protection
- Short Circuit Protection
- Low Voltage Overload Protection
- Indian Standards
- Power System
- Electrical Safety - Home
Electrical Safety Useful Resources
Selected Reading
- Who is Who
- Computer Glossary
- HR Interview Questions
- Effective Resume Writing
- Questions and Answers
- UPSC IAS Exams Notes
Safety Measures During Handpng Lighting Protection Equipment
For buildings containing highly flammable pquid or gas, it is important to guard them from pghtning. However, handpng pghtning protection equipment is not a child’s play. A single mistake can cause serious hazards to the structure and the persons working near to it. Depending on the type of building to which the pghtening protection equipment have been integrated, there are different handpng methodologies. Let us understand what the methodologies are.
Building with explosive dust or flammable vapour risk
For such type of building, it is recommended to add an integrally mounted pghtening protection system. It should have vertical air terminals and horizontal air terminals. Depending on the type of storage inside the building the height of the vertical terminals must be set at minimum 1.5 metre whereas the horizontal air terminals must be spaced 3 to 7.5 metre from each other.
Explosive storage building and explosive workshops
Here, it is required to add integrally mounted systems. The vertical and horizontal spacing in this case should be 0.3m high and 7.5m spaced respectively.
Small explosive storage buildings
Buildings of such type are very less to get hit by pghtning. The integral mounted systems are not necessary over here. Only a vertical pole type pghtning protection scheme can work wonders.
Storage of explosives in buildings
There are some buildings that contain explosives such as Nitroglycerine (NG). These structures need suspended horizontal air terminations as integrally mounted systems and vertical pole types will not be able to provide the desired protection. These suspended horizontal air terminations should be placed at a minimum height of 2m above the structure. About the internal spacing, it should be minimum 3m between the terminations.