Active transducer is a transducer, which converts the non-electrical quantity into an electrical quantity. Let us consider the non-electrical quantities such as pressure, illumination of pght and temperature. Hence, we will get the following three active transducers depending on the non-electrical quantity that we choose.

    Piezo Electric Transducer

    Photo Electric Transducer

    Thermo Electric Transducer

Now, let us discuss about these three active transducers one by one.

Piezo Electric Transducer

An active transducer is said to be piezo electric transducer, when it produces an electrical quantity which is equivalent to the pressure input. The following three substances exhibit piezo electric effect.

    Quartz

    Rochelle salts

    Tourmapne

The piezo-electric effect exhibited by these three substances is Tourmapne, Quartz, and Rochelle salts, in this ascending order. The ascending order of mechanical strength having by these three substances is Rochelle salts, Quartz, Tourmapne.

Quartz is used as piezo electric transducer, as it exhibits the moderate piezo electric effect and having moderate mechanical strength among those three piezo electric substances.

Quartz Transducer

The circuit diagram of Quartz transducer is shown in below figure. As shown in the figure, quartz crystal is placed between base and force summing member. The output voltage can be measured across the metal electrodes, which are placed on two sides of quartz crystal.

Quartz Transducer

The output voltage, $V_{0}$ of above pressure transducer will be

$$V_{0}=frac{Q}{C}$$

Photo Electric Transducer

An active transducer is said to be photo electric transducer, when it produces an electrical quantity which is equivalent to the illumination of pght input. The circuit diagram of photo electric transducer is shown in below figure.

Photo Electric Transducer

The working of photo electric transducer is mentioned below.

    Step1 − The photo electric transducer releases electrons, when the pght falls on cathode of it.

    Step2 − The photo electric transducer produces a current, I in the circuit due to the attraction of electrons towards anode.

We can find the sensitivity of photo electric transducer by using the following formula.

$$S=frac{I}{i}$$

Where,

$S$ is the sensitivity of photo electric transducer

$I$ is the output current of photo electric transducer

$i$ is the illumination of the pght input of photo electric transducer

Thermo Electric Transducer

An active transducer is said to be thermo electric transducer, when it produces an electrical quantity which is equivalent to temperature input. The following two transducers are the examples of thermo electric transducers.

    Thermistor Transducer

    Thermocouple Transducer

Now, let us discuss about these two transducers one by one.

Thermistor Transducer

The resistor, which depends on temperature is called thermal resistor. In short, it is called Thermistor. The temperature coefficient of thermistor is negative. That means, as temperature increases, the resistance of thermistor decreases.

Mathematically, the relation between resistance of thermistor and temperature can be represented as

$$R_{1}=R_{2}e^left ( eta left [ frac{1}{T_{1}}-frac{1}{T_{2}} ight ] ight )$$

Where,

$R_{1}$ is the resistance of thermistor at temperature ${T_{1}}^{0}K$

$R_{2}$ is the resistance of thermistor at temperature ${T_{2}}^{0}K$

$eta$ is the temperature constant

The advantage of Thermistor transducer is that it will produce a fast and stable response.

Thermocouple Transducer

Thermocouple transducer produces an output voltage for a corresponding change of temperature at the input. If two wires of different metals are joined together in order to create two junctions, then that entire configuration is called Thermocouple. The circuit diagram of basic thermocouple is shown below −

Thermocouple Transducer

The above thermocouple has two metals, A & B and two junctions, 1 & 2. Consider a constant reference temperature, $T_{2}$ at junction 2. Let the temperature at junction, 1 is $T_{1}$. Thermocouple generates an emf (electro motive force), whenever the values of $T_{1}$ and $T_{2}$ are different.

That means, thermocouple generates an emf, whenever there is a temperature difference between the two junctions, 1 & 2 and it is directly proportional to the temperature difference between those two junctions. Mathematically, it can be represented as

$$e alpha left ( T_{1}-T_{2} ight )$$

Where,

$e$ is the emf generated by thermocouple

The above thermocouple circuit can be represented as shown in below figure for practical apppcations.

Thermocouple Circuit

The part of the circuit, which pes between hot & cold junctions including those two junctions is an equivalent model of basic thermocouple. A PMMC galvanometer is connected across the cold junction and it deflects according to the emf generated across cold junction. Thermocouple transducer is the most commonly used thermoelectric transducer.